Smart High Sensitivity CCD Line Camera - Thorlabs, Inc.

文章推薦指數: 80 %
投票人數:10人

Thorlabs' LC100 Line Camera is designed for applications in optics, imaging, spectroscopy, biology, and industrial process control. It incorporates a 2048 pixel ...  ProductsHome / Detectors / CCD&CMOSCameras / SmartHighSensitivityCCDLineCamera SmartHighSensitivityCCDLineCamera 2048PixelLineArrayfor350to1100nm InputandOutputTriggers 5Logic-ControlledI/OPortsforPatternMatching StandaloneOperation 80mmx80mmx33mmHousingwithNikonF-MountandØ1/2"PostMountOptionLC100DefinitionofRegionsofInterestforSimplePatternMatchingRelatedItemsScientific-GradeCamerasCCDandCMOSCamerasF-MountAdapterLiquidCrystalTunableFilterVolumePhaseHolographicGratingsDoublePolarizerVariableAttenuatorsCMOSCameraLiquidCrystalOpticalShutterPowerandEnergyMetersUSBSpectrometersFiltersImagingSystemsOverview PleaseWaitOverviewSpecsUserInterfaceSoftwarePinConfigurationFeedback Specificationsa Item# LC100 DetectorRange(CCDChip) 350-1100nm ScanRateInternalTrigger Max900Scans/s CCDPixelNumber 2048 CCDPixelSize 14µmx56µm(14µmPitch) CCDSensitivity 240V/lxs CCDDynamicRange 333 IntegrationTime 1ms-50s S/NRatio 2000:1 Forcompletespecifications,pleaseseethe Specstab. Features InputandOutputTriggers 5User-ConfigurableGeneralPurposeInput/OutputPorts(GPIO) Upto16IndependentlyProgrammableRegionsofInterest InternalSimplePatternMatchingLogic StandaloneOperation AdapterforF-MountObjectives Compatiblewith30mmand60mmCageSystemsandSM2LensTubes Ø1/2"PostMountable F-MountCompatibleviaIncludedAdapter VersatileSoftwarePackage(Splicco)andDriverPackage(C/C++,VB,DotNet,LabVIEW)Included USB2.0Interface PoweredviaUSB Dust-Proof,RuggedHousingSuitableforField Applications Thorlabs'LC100LineCameraisdesignedforapplicationsinoptics,imaging,spectroscopy,biology,andindustrialprocesscontrol.Itincorporatesa2048pixelCCDarrayandiscapableofdetectinglightinthe350-1100nmrange.Withscanratesupto900scanspersecond(450Hzwithexternaltrigger),thislinecameraofferstriggerinputandoutput,ananalogoutput,andfivedigitalsoftware-controlledGeneralPurposeInput/Outputs(GPIOs).Thedelayoftheinputandoutputtriggerscanbeadjusted,andtheanalogoutputmonitorstheintensityofaselectablesinglepixeloftheline. TheLC100linecameraiscapableofanalyzingupto16freelydefinableregionsofinterest(ROIs)fromtherecordedlinescans;itcananalyzeeachspectrumindependentlyusingsimplepatternmatching.ThefiveGPIOscanbeprogrammedtoreturnspecificlogicpatternsaccordingtotheresultsofthespectrumanalysis.Sinceversion4.3oftheSPLICCOsoftwarepackagetheLC100featuresastandalonemodethatallowsthelinecameratoperformthisanalysiswithoutbeingconnectedtoaPC. ClicktoEnlargeTheLC100withaNikonF-Mountcameralens(notavailablefromThorlabs)mountedviaanSM2NFM F-MounttoSM2threadadapter. ClicktoEnlargeTheLC100witha60mmcagesystem. Therugged,dust-proofhousingmakestheLC100linecamerasuitableforfieldapplicationsandprocesscontrol.Typicalapplicationsincludeusingthelinecameraasasensorincustomspectrometersorinterferometersaswellaspositionorsizesensingdevices.Thesecamerasarealsousedindefectsensingapplicationsaswellasforfilllevelandedgedetection. MountingOptionsThehousinghaseight4-40taps,makingit compatiblewithour 30mmCageSystemsand60mmCageSystems.Inaddition,thehousingisSM2(2.035"-40)-threadedforØ2"LensTubecompatibility.A1/4"-20(M6)tapisprovidedforØ1/2"postmounting. TheLC100(/M)willberetiredwithoutreplacementwhenstockisdepleted.Ifyourequirethispartforlineproduction,pleasecontactour OEMTeam. Item# LC100a SensorSpecs DetectorRange(CCDChip) 350-1100nm CCDPixelSize 14µmx56µm(14µmpitch) CCDSensitivity 240V/(lx·s) CCDDynamicRangeb 333 CCDPixelNumber 2048 IntegrationTimec 1.055ms−50s ScanRateInternalTrigger Max900Scans/sd S/NRatioe,f ≤2000:1 ExternalTrigger TriggerInput BNC TriggerSignal TTL5Vand3.3V TriggerFrequency,ScanRate Max450Hz,450Scans/sd TriggerPulsLength Min50ns TriggerDelay 4.5µs GeneralPurposeInput/Output(GPIO)Type 3.3VTTL NumberofGPIOs 5 RegionofInterests(ROI) 16 AnalogOutput Programmable0-4V GeneralSpecs Interface Hi-SpeedUSB2.0(480Mbit/s) Dimensions(LxWxH) 80mmx80mmx33mm(3.13"x3.13"x1.30") Weight <0.4kg Alltechnicaldataarevalidat23±5°Cand45±15%relativehumidity(noncondensing). RatioofSaturationVoltagetoDarkCurrentVoltage ExposureTime 1.055msIntegrationTime;Dependentupon ConnectedPC 10xAveraging;DependentuponInegrationTime UseCCDDynamicRangeforSingleShots ClicktoEnlarge ClicktoEnlarge GraphicalUserInterfaceAdjustableParametersIntegrationTimeTriggerModes:Internal,External,Continuous,SingleShotAveragingMethod:GlidingorBlockAverageSmoothingMethod:BlockSmoothingPictureFlipandRevertFeaturesOperatesupto10DevicesSimultaneouslyAuto-DetectionofCompatibleDevicesAvailableFilters:PeakFinder,Smoothing,Averaging,Flip/RevertPictureAlgorithms:GaussianTransformationNormalizedYAxisPersistenceOptionDifferentThreadforDataAcquisitionforBetterResponsivenesstoUserInputUserSelectableColorsSavingandRetrievalofScans(JCAMP-DXorCSV)CopyFunctiontoClipboardPrintableWindowsTabbedorFloatingWindowsGaussianDataFittingTheLC100SeriesLineCameraisfeaturingtheeasy-to-useSPLICCOsoftwarewithgraphicaluserinterface.Thepackageisdesignedforlaboratoryandmanufacturingapplications.Thedata,background,andpeakscanbeshowninasinglegraph.Withthehelpofsmoothingandaveragingalgorithmstheuserisabletoenhancespecificfeaturesofthespectra.Furthermorethesoftwareisabletohandleseveraldevicesatonetimewhicharepresentedindifferentwindows.Theabovescreenshowsthepeakfinderscreenthatlistsallpeakswithagivenminpeak-height(threshold)andpeakwidth.SPLICCOalsoallowstorecordscanssequentially,seeSequentialRecordingbelow.SimplePatternMatchingFortheLC100youcandefineupto16areasofinterest(Evalboxes)withadjustablesizesatarbitrarylocationsintheIntensityvs.Pixelpane.Theywillbeinterrogatedduringscans.Theresultcanbeusedforsimplepatternmatchingandconnectedwithcustomizedlogictooneofthe5GeneralPurposeInputOutputs(GPIO).EditableAxesYoucaneasilysetthedisplayedrangeofthemeasuredintensitybyenteringtheminandmaxvaluesattheyaxisoftheintensityplot.SequentialRecordingTheSPLICCOsoftwareallowstosequentiallyrecordindividualscansinCSVfileformat.Amaximumof1000scanscanberecordedatarateofupto900scanspersecond. SoftwareforSpectrometersandUSBLineCameras ThispackagealsoincludestheinstrumentdriversfortheNationalInstruments™,LabWindows™/CVI,andLabVIEW™*developmentenvironments.Thedriversareintendedfordeveloperswhowanttoextendoradaptthefunctionalityofthedevicetotheirspecialrequirements. Software Version4.3 Standardfullsoftwareapplicationpackagesandgraphicaluserinterfaces. OR AdvancedBetaVersion* Version4.5.103.788(April22,2013) Fullsoftwareversionsoftwareapplicationwithlatestbugfixes: ImprovedVXIpnpcompatibility Includes64bitversionsofLabVIEWdrivers/examples *Thisreleasecandidatesoftwareversion,whichincorporatesnewfeaturesand/orbugfixesasoutlinedinthechangelogfileonthedownloadpage,hasbeenthroughseveralroundsoftestingandtherearecurrentlynosignificantbugs.Oncefulltestinganddocumentationisavailable,thisversionwillbecomethestandardsoftwarepackage.Intheinterim,Thorlabsismakingthiscompletesoftwarefileavailableforthosecustomerswhoseresearchendeavorswouldbenefitfromtheupdatedfeatures. PinConfigurationofTriggerCableConnectorConnectorPinsPin#Description 1TriggerInput,LLTTL2CommonGND(TriggerandGPIO)3AnalogOutput4-8GPIOPorts1-5,LLTTLPleaseGiveUsYourFeedback1.FirstName 2.LastName SubmitAnonymously:3.Email ContactMe:4.FeedbackOn ALLPRODUCTSPresentationFeedbackLC-100LC-100/MLC100LC100/MPrefertoRequestaQuote?RequestQuote5.EnterCommentsBelow:Charactersremaining 8000   6.SubmitFeedback:CharactersareCase-SensitiveClickforanewcode.PostedComments:laurentbruel &nbsp(posted2021-06-0808:32:11.88)Wedon'tuseanymorewindows/labviewandIwouldliketousethiscamerawitharaspberrypi4underraspbianwithUSBconnection. Haveyougotsomedocumentationaboutthis? Someothermodeltocomelater?wskopalik &nbsp(posted2021-06-1010:45:31.0)Thankyouverymuchforyourfeedback! Unfortunately,thesoftwareanddriverfilesfortheLC100(/M)camerasareonlyavailableforWindowssystemsandwedonothaveanyfilesordocumentationforLinux/Raspbian. Iwillcontactyoudirectlytodiscusspossiblesolutionsforyourapplication.RaghunathPatil &nbsp(posted2021-05-2400:12:06.34)Wewantcameraforgrainsortingpurpose.soswald &nbsp(posted2021-05-2608:48:58.0)DearRaghunath, thankyouforyourfeedback.Ihavecontactedyoudirectlytofurtherdiscusstherequirementsofyourapplication.MartinPaur &nbsp(posted2020-06-3006:42:00.283)Hi,isitpossibletogetadditionalinformationaboutthesensortypeandvendor?Wewouldliketoknowifthecameraisfront-illuminatedorback-illuminated,becauseofthe"OpticalEtaloning"probleminNIRspectralregions.MKiess &nbsp(posted2020-07-0305:45:55.0)ThisisaresponsefromMichaelatThorlabs.Thankyouverymuchforyourinquiry.ThesensorisaSonyILX554B.YoucanfindtheSpecSheetintheLineCameradocumentsonourwebsite.Ihavealsosentittoyouviae-mail.ChristopherVanArsdale &nbsp(posted2019-11-1716:51:32.973)CanthiscameraoperateasanormalUSB(UVC)camerawithoutacustomdriver(on,say,LinuxorMacOS)?dpossin &nbsp(posted2019-11-2008:54:01.0)DearChris, Thankyouforyourfeedback.ThelinecameraLC100canbeusedwiththesoftwareweprovideonourhomepageaswellaswithC,C++,CVI,C#,VisualStudioorLabView.UnfortunatelyLinuxandMaxOSiscurrentlynotprovided.user &nbsp(posted2019-02-1008:28:46.96)450fpsistooslowformyapplication.Isthereafastercameraintherangeof10kfps?wskopalik &nbsp(posted2019-02-1907:17:04.0)ThisisaresponsefromWolfgangatThorlabs.Thankyouverymuchforyourinquiry! Unfortunately,neitherthelinecameranorourothercamerascanachievesuchhighframerates.Thereasonsforthisaremainlylimitationsintheexposuretimeandthedatatransferfromthecameratothecomputer. Pleasefeelfreetocontactourtechnicalsupportteamsifyouhaveanyfurtherquestionsaboutourcameras.Wewouldbehappytoassistyou!jbcrossrvg &nbsp(posted2018-04-1708:11:29.8)WouldaMACversionofSoftwareforSpectrometersandUSBLineCamerasbeavailable?swick &nbsp(posted2018-04-2004:07:33.0)ThisisaresponsefromSebastianatThorlabs.Thankyoufortheinquiry.ForLC100wedonotoffersoftwareversionswhicharecompatibletoMacOS.tbaker1 &nbsp(posted2018-02-1214:15:31.203)Istherearecommendedlenssystemthatyousuggesttogoalongwiththiscamera?Thepreferredapplicationwouldbemachinevisionatlikea1:1magsooneoftheobjectiveslistedonthe"CameraLensesforMachineVision"wouldwork.Thanksforanyrecommendations.swick &nbsp(posted2018-04-2003:54:28.0)ThisisaresponsefromSebastianatThorlabs.Thankyoufortheinquiry. Mostapplicationsforcamerasrequireindividuallenssystemsduetorequirementsoftheparticularapplicatione.g.FOV,minobjectdistance. OurcameraobjectivesdohaveaC-mountthreadhencetheyarenotdirectlycompatibletotheLC100.WeofferanadapterforC-mount(SM2A54)butitdoesnotguaranteethecorrectflangefocaldistance.Icontactedyoudirectlyforfurtherdiscussion.przemyslaw.gontar &nbsp(posted2017-11-2110:53:57.783)Hello,Ihaveproblemwithscaning.IplugeddeviceviaUSBandinincludedsoftwareandinmyownwritedinMatlabihavetimeouterrors.Icanscanmax10secindiferentintegrationsscansothismakehardtomeasureforlongertime.Whatcancausethiserrorandhowcanitbesolved?Bestregards.wskopalik &nbsp(posted2017-11-2203:09:24.0)ThisisaresponsefromWolfgangatThorlabs.Thankyouverymuchforyourinquiry! Iwillcontactyoudirectlytotroubleshootthisissueinmoredetail.hitesh.mamgain &nbsp(posted2016-10-2001:07:05.42)HI, IwantedtoknowifthiscamerahasanSDKofanykindsothaticanreadythespectruminmyownsoftware?swick &nbsp(posted2016-10-2103:28:04.0)ThisisaresponsefromSebastianatThorlabs.Thankyoufortheinquiry. InthemanualofLC100(/M)atChapter5,"WriteYourOwnApplication",youcanfinddetailedinformationabouttheinstrumentdriversandprogrammingenvironments(C#,C++,Labview). Ihavecontactedyoudirectlytoprovideassistance.arvinmabilangan &nbsp(posted2016-05-0205:08:00.25)Hello,IboughtyourLC100cameraformyopticalsetup.I'mhavingtroublemakingmyownLabViewcodeforit.I'mspecificallyhavingerrorsinoperatingthecamerainExtTriggermode.DoyouhavesampleLabViewcodesfeaturingexternaltriggers?Thanks!shallwig &nbsp(posted2016-05-0208:45:29.0)ThisisaresponsefromStefanatThorlabs.Thankyouforyourinquiry,wewillcontactyoudirectlytotroubleshootthisindetail.did4730 &nbsp(posted2016-02-2522:25:29.487)Hello.yesterdayLC100deliveredtome.AndIfounddriverpackageforvb6Buti'mhavingtroublemakingvb6codeformyownapplication.couldIgetavb6example?shallwig &nbsp(posted2016-02-2511:20:49.0)ThisisresponsefromStefanatThorlabs.Thankyouforyourinquiry.Wewillcontactyoudirectlytotroubleshootthisindetail.did4730 &nbsp(posted2015-12-2808:03:18.667)Hello.Iwanttooperatefourlinecamerassimultaneouslyformyapplication.couldyouletmeknowitispossible?bestregards.tschalk &nbsp(posted2015-12-2805:09:07.0)ThisisaresponsefromThomasatThorlabs.Thankyouverymuchforyourinquiry.YoucanuseourSoftwareSPLICCOtorunfourlinecamerasLC100simultaneously.Iwillalsocontactyoudirectlywithmoredetailedinformation.thha &nbsp(posted2015-12-1605:23:05.0)Today,LC100delieriedtome. Ididn'tcheckbeforeorderit.CouldigettheimageusingLC100andsoftware? Ithink,yoursoftwarejustshowingtheintensityofsingel.Itdoesn'thaveanyimagefunctions. IwanttomaketheSLO(ScanningLaserOphthamicscope). Itispossiable?Letmeknowyourcomments. BestRegards.besembeson &nbsp(posted2015-12-1601:15:45.0)ResponsefromBwehatThorlabsUSA:ThanksforcontactingThorlabs.Youarecorrectthisgivesyouanintensityprofileofeachlinescan.Youcanthencollectseverallinescansandperformimagereconstructionviaexternalsoftware.Sequentialrecordingofindividuallinescansisalsopossiblewiththecamerasoftware.IwillcontactyoutofurtherdiscussyourSLOapplication.sebastien.avila &nbsp(posted2015-06-1511:56:54.607)Hello, WearehavingthreeproblemswithcameraLC100andSPLICCOsoftware: -whenrecordingdatain"SEQUENTIALRECORDING"mode,theerrormessageappearsanddataislost -Whendataisrecorded,themaximumvalueis0.8andnot1asseeninthegraph -Sometimes,intensitypeaksveryhighsuddenly,andcomesbacktonormalvalue WeuseSPLICCO4.3softwarefromtheinstallationCDpackedwiththecamera. Aretheotherversions(4.2or4.5)betteroptionsforstability? Thankyouverymuch.shallwig &nbsp(posted2015-06-1509:11:29.0)ThisisaresponsefromStefanatThorlabs.ThankyouforcontactingusandpleaseapologizetheproblemsyoufacewiththeSPLICCOsoftwareandlinecamerahere.Ihavecontactedyoudirectlytotroubleshootthisindetail.dbuenoba &nbsp(posted2015-03-2601:12:24.023)Hello!CouldyoupleasekindlyprovideanANSICexampleforacontinuousHWtriggerdataacquisition?Inparticular,couldyoupleaseclarifyhowtoaccess/grabthedataaftereachsuccessiveconversion?Thanks!!shallwig &nbsp(posted2015-03-2709:48:22.0)ThisisaresponsefromStefanatThorlabs.Thankyouverymuchforyourinquiry.Whendownloadingthedriversfromourwebsitewithoursoftwarehttp://www.thorlabs.com/software_pages/ViewSoftwarePage.cfm?Code=SPLICCOtherewillautomaticallydownloadanexampleinC.Fora32bitsystemyoucanfinditunderthefollowingpath:C:\ProgramFiles\IVIFoundation\VISA\WinNT\ThorlabsLC100\Examplesandfor64bitsystemsunderC:\ProgramFiles\IVIFoundation\VISA\Win64\ThorlabsLC100\Examples Inthisisexampleitisalsodescribedhowtoaccessthedata.RegardingaCsampleparticularlyforcontinuoushardwaretriggeracquisitionIwillcontactyoudirectly.ditlacio &nbsp(posted2014-06-1421:15:41.38)Needafasterdetection,andahigherS/Nratio. Doyouhavesuchalineccd?Imlookingfora10microsecresponseandatleasta20000:1s/n. needittomeasureobticaldensityinthinobjetcsshallwig &nbsp(posted2014-06-1704:56:01.0)ThisisaresponsefromStefanatThorlabs.Thankyouverymuchforyourinquiry.AtthemomentunfortunatelyweonlyhavethelinecameraLC100withthespecsshownonthewebsitehere:http://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=5290&pn=LC100#5291 Theintegrationtimeis1.055ms–50SandtheScanRateInternalTriggerallowsmaximal900scans/sattheminimalintegrationtime.Wespecifythesignaltonoiseratiowith?2000:1dependingontheintegrationtime.Perhapsinthefuturewecanofferalinecamerawhichmeetsyourrequirementsbetter.Iwillcontactyoudirectlytodiscussyourapplicationindetail.user &nbsp(posted2013-08-2013:25:51.137)Howcanyouusethedivision,transmittance,absorbanceinsteadofthescopefunction?IsitpossibletouseoneextraLC100asrealtimereferencewiththeSPLICCOsoftware?tschalk &nbsp(posted2013-08-2104:26:00.0)ThisisaresponsefromThomasatThorlabs.Thankyouverymuchforyourinquiry.Itispossibletostoretheactualmeasurementplotasthereferenceplot.Toachievethebutton"StoreasactualReference"canbeused.DetailedinformationabouttheReferencecanbefoundinthemanual(https://www.thorlabs.de/Thorcat/20300/LC100_M-Manual.pdf)insection3.19"References".IfaCompactCCDSpectrometer(https://www.thorlabs.de/newgrouppage9.cfm?objectgroup_id=3482)isconnectedyouhavethepossibilitytousethefunctionsDivision,Absorbance,TransmittanceandDifference.Inthecasethatalinecameraisusedthesefunctionsarenotavailable.WiththecurrentversionitisnotpossibletouseasecondLC100asarealtimereference.ItwouldbegreatifyoucouldcontactmedirectlyatEurope@Thorlabs.comtodiscussyourapplication.cbrideau &nbsp(posted2013-08-1918:00:50.583)Iaminterestedinusingthestand-alonecapabilityofthiscameraforanapplication.IsitpossibletotellthecameratosnapabackgroundspectraandapplyitagainstfurtheracquisitionsusingtheGPIO,oristhissomethingthatcanonlybedoneviaconnectiontoaPC?I'dliketopresentasampleholdertothecamera,pushabuttontoestablishthebaseline,thenaddmysampleintotheholderandhaveGPIOpinsgohighwiththedetectionofacertainpeak,subtractingthebaselinebeforethesystemdecideswhetherthepeakisthereornot.tschalk &nbsp(posted2013-09-2311:37:00.0)ThisisaresponsefromThomasatThorlabs.Thankyouverymuchforyourinquiry.ItispossibletosettheGPIOPintohighifacertainpeakisdetected.ItisnotpossibletosubtractthebackgroundspectrausingtheGPIO.Thereforethecomputersoftwarecanbeused.Iwillcontactyoudirectlywithmoredetailedinformation.vlad &nbsp(posted2013-04-2613:13:04.587)Hello, IaminterestedintheUV-sensitiveLC100camera. "FutureversionsoftheLC100SeriesfortheUVspectralregionwillbeofferedsoon." HowsoonwilltheLC100-UVbeoffered? Thankyou. VladSoukhanovskii ============================================ VladSoukhanovskii,Ph.D. Physicist FusionEnergySciencesProgram,L-637 LawrenceLivermoreNationalLaboratory 7000EastAve.,Livermore,CA94551-9900 Email:[email protected] _______________________________________ Onresearchassignmentat PrincetonPlasmaPhysicsLaboratory MS34,P.O.Box451,Princeton,NJ08540 OfficePhone:609-243-2064 GeneralOfficeFax:609-243-2874 ============================================tschalk &nbsp(posted2013-05-0610:59:00.0)ThisisaresponsefromThomasatThorlabs.Thankyouverymuchforyourinquiry.AtthemomentwearenotplaningtoreleaseaLC100camerawhichissensitiveforUVLightasastandarditem.MaybewecanofferyouacustommadeitemwhichismoresensitivetoUVLight.Iwillcontactyoutodiscussthedetails.jlow &nbsp(posted2012-08-1409:04:00.0)ResponsefromJeremyatThorlabs:Wedoprovidethetriggerinputcable.Both5Vand3.3VcanbeusedforTTLtriggersignal.Also,thetriggerinputisnotopto-isolated.v.fadone &nbsp(posted2012-08-1410:50:31.0)DearSirs, IneedtosynchronizeLC100toanexternalsourcesoI'lluseTriggerInputonGPIOconnector.AsIcanunderstandfromthemanual,ThorlabsprovidesacablewithaBNCconnector.Isitcorrect?Thetriggervoltagerangeshouldbe0-3.3V(LLTTL)butontable6.1IreadTTL5Vand3.3V.Isitpossibletouseboth5Vand3.3VTTLtriggersignal?Isthetriggerinputoptoisolated?ThanksVannijvigroux &nbsp(posted2012-07-1606:57:00.0)AresponseformJulienatThorlabs:Thankyouforyourinquiry!TheLC100canbereadoutthroughMatlab.ThedriverisaVXIPnPdriverandcanthusbeimportedintoMatlabusingtheinstrumentcontroltoolbox.dk &nbsp(posted2012-07-1507:24:35.0)DearThorlabsteam,isthereachancetocontrolandreadtheLC-100linecamerafromMatlab?Whatwouldwehavetodotoachievethis? Thanks Danieltcohen &nbsp(posted2012-03-2213:09:00.0)ResponsefromTimatThorlabs:Thankyouforyourfeedback.FornowyoucanfindthisinformationneartheendoftheoverviewtabaswellasbyopeningtheCADdrawingbyclickingtherediconnexttotheproductname.Forfuturevisitorswewillupdateourwebpresentationtomakethisinformationmorereadilyavailableandobvious.user &nbsp(posted2012-03-2210:41:32.0)Itappearsthattherearethreadsonthisdevicebutdon'tseeanydetails,pleaseconsideraddingthisinformation.bdada &nbsp(posted2012-02-1315:41:00.0)ResponsefromBukiatThorlabstowzc0014: ThankyouforyourfeedbackontheLC100.IfyouclicktheredpageicontotheleftoftheLC100partnumberyoucanopenthemanualoftheLC100.Onpage15ofthemanual,itisstatedthattheintegrationtime(thetimerepresentinghowlongtheCCDinteractswithincominglight)oftheCCDissupportedbetween1.054msto50sandcanbesetviatheSPLICCOsoftware.Theintegrationtimeisalsoincludedinthe"Specs"tab. Belowisalinktothemanual: http://www.thorlabs.com/Thorcat/20300/20308-D02.pdf PleasecontactTechSupport@thorlabs.comifyouhaveanyfurtherquestions.wzc0014 &nbsp(posted2012-02-1311:54:41.0)Anyinformationontheexposuretime,andarangeorcontroloverit?jjurado &nbsp(posted2011-05-1817:52:00.0)ResponsefromJavieratThorlabstodaniel.j.breton:Thankyouverymuchforcontactingus.Wedonotrecommendusingthiscameraat-20°C,sincetheoperatingtemperaturerangeofthesensorisratedat-10to60°C.Unfortunately,wedonotcarryorknowofotherlinecamerasthatwouldperformwellat-20°C.Iwillcontactyoudirectlyforfurthersupport.daniel.j.breton &nbsp(posted2011-05-1816:11:14.0)Reviewingyourspecsandthemanual,Idonotseeanoperatingtemperaturespec.Canthisthingrunat-20C?Areanyotherlinescancamerasavailablethancan?jvigroux &nbsp(posted2011-05-1806:39:00.0)AresponseformJulienatThorlabs:Thankyouforyourfeedback.Thisisindeedanoptionwehaveconsidered.Duetothenumerouspossibilitiesbothintermsofsetupsandapplications,wehoweverdecidednottogothiswayaswewouldhaveneededanequalnumberofkits.Weofcoursearehappytohelpputtingtogetherthenecessarypartsforagivenapplication.Iwillcontactyoudirectlyperemailinordertodiscussthedetailsofyours.cbrideau &nbsp(posted2011-05-1712:58:24.0)ItwouldbereallyusefultosellthisaspartofakitwiththeCVH100cuvetteholder.Atransmissiongrating,acouplelenses,andsomecageandcubepartsandyoucouldintegratethisthingasaspectrometertothesideoftheCVH100.Youcouldsellthekitwithdifferentgratingsfordifferentspectralranges.SmartCCDLineCameraBasedonyourcurrency/countryselection,yourorderwillshipfromNewton,NewJersey  +1QtyDocsPartNumber-ImperialPriceAvailableLC100SmartLineCamera,USB2.0,350-1100nm,2048PixelLinearSiCCDArray$1,418.63Today+1QtyDocsPartNumber-MetricPriceAvailableLC100/MSmartLineCamera,USB2.0,350-1100nm,2048PixelLinearSiCCDArray,MetricThread$1,418.63LeadTimeAddToCart×SubscribetobeNotifiedAboutUpcomingWebinars!*FirstNameRequired*LastNameRequired*EmailRequiredCompany/InstitutionJobTitleCharactersareCase-SensitiveClickforanewcode.AdditionalCCD&CMOSCamerasScientificCameraSelectionGuide1.6MPCMOSCompactScientificCameras1.3MP-12.3MPCMOSCompactScientificCameras5.0MPCMOSCompactScientificPolarizationCamera2.1MPsCMOSCompactScientificCamerasFastFrameRate,VGACCDScientificCameras1.4MPCCDScientificCameras8.0MPCCDMicroscopyCamerasLinearCCDCameraCameraLenses,Objectives,andMountsIntrotoCameraTerminologyCameraNoiseTutorialCustom/OEMMicroscopyCamerasCameraSoftwareDownloads



請為這篇文章評分?